SCALANCE network components
4.9 Network management software
Industrial Ethernet
276 System Manual, 09/2019, C79000-G8976-C242-10
It is possible to set addresses for the following SIMATIC NET network components using
PST:
SCALANCE W-700
SCALANCE X-200
SCALANCE X-300
SCALANCE X-400
SCALANCE X-500
It is possible to set addresses for the following Ethernet CPs using PST:
CP 343-1
CP 443-1
It is possible to set addresses for the following SIMATIC NET gateways using PST:
IE/PB LINK
IE/PB-LINK PN IO
IWLAN/PB LINK
DCP protocol and DLC protocol
The Primary Setup Tool uses the protocols DCP (Discovery and basic Configuration
Protocol) and DLC (Data Link Control) for communication with the modules. The DLC
protocol is necessary for devices with older firmware versions.