SIMATIC Instructions
9-34
S7-200 Programmable Controller System Manual
A5E00066097-02
Table 9-6 HSC1 Modes of Operation (CPU 224 and CPU 226)
HSC1
Mode Description I0.6 I0.7 I1.0 I1.1
0 Single phase up/down counter with internal direction control
1
SM47.3 = 0, count down
=
p
Clock
Reset
2
.
=
,
Start
3 Single phase up/down counter with external direction control
4
I0.7 = 0, count down
p
Clock Dir.
Reset
5
.
=
, coun
up
Start
6 Two-phase counter with count up and count down clock
7
inputs Clock
Up
Clock
Dn
Reset
8
Start
9 A/B phase quadrature counter,
10
phase A leads B by 90 degrees for clockwise rotation,
p
hase B leads A by 90 degrees for counterclockwise
Clock
Phase
Clock
Phase
Reset
11
rotation
A
B
Start
Table 9-7 HSC2 Modes of Operation (CPU 224 and CPU 226)
HSC2
Mode Description I1.2 I1.3 I1.4 I1.5
0 Single phase up/down counter with internal direction control
1
SM57.3 = 0, count down
p
Clock
Reset
2
.
=
, coun
up
Start
3 Single phase up/down counter with external direction control
4
I1.3 = 0, count down
p
Clock Dir.
Reset
5
.
=
, coun
up
Start
6 Two-phase counter with count up and count down clock
7
inputs Clock
Up
Clock
Dn
Reset
8
Start
9 A/B phase quadrature counter, Clock
Clock
10
phase A leads B by 90 degrees for clockwise rotation,
p
hase B leads A by 90 degrees for counterclockwise
Phase
A
Phase
B
Reset
11
rotation
Start