Basic Concepts for Programming an S7-200 CPU
4-31
S7-200 Programmable Controller System Manual
A5E00066097-02
Using a Status Chart to Monitor and Modify Your Program
As shown in Figure 4-16, you can use a Status Chart to read, write, force, and
monitor variables while the program is running. Use the menu command View >
Status Chart.
The status chart toolbar icons are shown in the STEP 7-Micro/WIN 32 toolbar
area. These toolbar icons (Sort Ascending, Sort Descending, Single Read,
Write All, Force, Unforce, Unforce All, and Read All Forced) are enabled when
you select the status chart.
You can create multiple status charts.
To select a format for a cell, select the cell, then press the right mouse button to
enable the drop-down list (Figure 4-16).
Status Chart
Address Format New ValueCurrent Value
Bit
Bit
Bit
Bit
Bit
Start_1
Bit
Bit
Bit
Bit
Bit
2#0
2#0
2#0
Start_2
Stop_1
Stop_2
High_Level
Low_Level
Reset
Pump_1
Pump_2
Mixer_Motor
Steam_Valve
Drain_Valve
Drain_Pump
Hi_Lev_Reached
Mix_Timer
Cycle_Counter
Bit
Bit
Bit
Bit
Signed
Signed
2#0
2#0
2#0
2#0
2#0
2#0
2#0
2#0
2#0
2#0
+0
+0
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CHT1
Cut Ctrl+X
2#0
Copy Ctrl+C
Paste Ctrl+V
Force
Unforce
Insert
Delete
Define Symbol...
Figure 4-16 Monitoring and Modifying Variables with a Status Chart