S7-200 Specifications
A-63
S7-200 Programmable Controller System Manual
A5E00066097-02
6M_supp = 1
12M_supp = 1
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_45.45 = 250
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
Redundancy = 0
Repeater_Ctrl_Sig = 2
24V_Pins = 2
; Slave-Specification:
OrderNumber=”6ES7 277-0AA20-0XA0”
Periphery=”SIMATIC S5”
Slave_Family=10@TdF@SIMATIC
Freeze_Mode_supp = 1
Sync_Mode_supp = 1
Set_Slave_Add_Supp = 0
Auto_Baud_supp = 1
Min_Slave_Intervall = 1
Fail_Safe = 0
Max_Diag_Data_Len = 6
Modul_Offset = 0
Modular_Station = 1
Max_Module = 1
Max_Input_len = 128
Max_Output_len = 128
Max_Data_len = 256
; UserPrmData-Definition
ExtUserPrmData=1 ”I/O Offset in the V-memory”
Unsigned16 0 0-5119
EndExtUserPrmData
; UserPrmData: Length and Preset:
User_Prm_Data_Len=3
User_Prm_Data= 0,0,0
Max_User_Prm_Data_Len=3
Ext_User_Prm_Data_Const(0)=0x00,0x00,0x00
Ext_User_Prm_Data_Ref(1)=1
; Module Definition List
Module = ”2 Bytes Out/ 2 Bytes In -” 0x31
EndModule
Module = ”8 Bytes Out/ 8 Bytes In -” 0x37
EndModule
Module = ”32 Bytes Out/ 32 Bytes In -” 0xC0,0x1F,0x1F
EndModule
Module = ”64 Bytes Out/ 64 Bytes In -” 0xC0,0x3F,0x3F
EndModule
Module = ”1 Word Out/ 1 Word In -” 0x70
EndModule
Module = ”2 Word Out/ 2 Word In -” 0x71
EndModule