3. Insert FAT32-based USB ash disk into DCR.
4. Generate nxgupdate key via keypad parameter 7752.
– The le should be created within 30 seconds.
– You can remove the USB ash disk, insert into PC to check le creation. If trying to update
base software, then re-insert into DCR.
5. STOP HERE IF YOU ARE ONLY CREATING THE KEY
CAUTION
STOP HERE IF YOU ARE ONLY CREATING THE KEY
STOP HERE IF YOU ARE ONLY CREATING THE KEY; REMOVE USB FLASH DISK. PROCEEDING
WILL RESET YOUR DCR AND ERASE ALL SAVED PARAMETERS ON DCR.
6. From ToolSuite Utilities tab, press NXGPro+ Initial Program button.
7. Select the NxGproPlus_vXXYYZZ_RNNN.init le, where XX, YY, ZZ is version and NNN is
release number. Wait for "Successfully loaded initialization le" success dialog and select OK.
Renaming "init" les IS NOT SUPPORTED; if renamed, the le will be ignored.
8. Reboot DCR (leave USB ash disk inserted).
9. Wait approximately 5-7 minutes for Green LED blink 7x repeatedly.
– If it does not (e.g. Red LED blink 15x repeatedly), recover FAILED
– If the DCR boots up normally and you can connect via Drive Tool or Debug Tool, then the
USB ash drive was not recognized. Try another brand and/or model.
10.Remove USB ash disk from DCR.
11.Reboot DCR.
12.After ~60-90 seconds, you should be able to connect using Drive Tool and Debug Tool using
default IP conguration.
13.Now you will be able to reload customer-specic parameter conguration le and SOP le
from your PC.
14.Then reboot DCR again.
Software user interface
9.4 Security Measures
NXGPro+ Control Manual
402 Operating Manual, A5E50491925A