9.11 Diagnosis via STARTER
Commissioning
9-114
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
Further signal forms
Further signal forms can be produced by parameterization.
Example:
The “triangular” signal shape can be parameterized with “upper limitation” to produce a
triangle with no peak.
Upper
limiting
Signal form
“Triangular”
Fig. 9-14 “Triangular” signal without peak
Starting/stopping the function generator
!
Caution
With the corresponding ramp-function generator parameter settings (e.g. offset), the motor
can “drift” and travel to its end stop.
The motion of the drive is not monitored with the function generator activated.
To start the function generator, proceed as follows:
1. Provide for the prerequisites for starting the function generator.
Activate the control panel.
Drives –> Drive_x –> Commissioning –> Control board
Turn on the drive.
Control board –> Issue enable signals –> Switch on
2. Select the appropriate operating mode,
e.g. speed setpoint downstream of the filter.
3. Select the drive (as the control panel).
4. Set the signal form,
e.g. rectangle.
5. Load the settings to the target system (“Download parameters” pushbutton)
6. Start the ramp-function generator (“Start FctGen” pushbutton)
To stop the function generator, proceed as follows:
“Stop FctGen” pushbutton

Table of Contents

Other manuals for Siemens SINUMERIK 802D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D sl and is the answer not in the manual?

Siemens SINUMERIK 802D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D sl
CategoryController
LanguageEnglish

Related product manuals