Technical Data
8-77
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
Digital outputs of the PP72/48 (as per IEC 1131-2 / DIN EN 61131-2)
Table 8-4 Digital outputs of the PP72/48 I/O module
Number of outputs
16 each per terminal strip converter
Parameter min. typical max. nominal
Voltage with high level (U
H
)
V
CC
– 3 V
1)
V
CC
24 V
I
out
– – 0.25 A
–
Voltage with low level (U
L
)
– – –
Output
open
Leakage current at low signal level
– 50 µA 400 µA
–
Signal delay time T
PHL
2)
– – 0.5 ms –
max. switching frequency
2)
S ohmic load
S inductive load
S lamp
100 Hz
2 Hz
11 Hz
–
–
–
–
–
–
–
–
–
1)
Supply voltage for the digital outputs
Typical output voltage: V
CC
– I
OUT
* R
ON
V
CC
: Current operating voltage
Max. output currentI
OUT
: 0.25 A
Max. short-circuit current: 4 A (max. 100 µs, V
CC
= 24 V)
Internal resistanceR
ON
: 0.4 Ω
2)
In addition, take into account the PROFIBUS DP communication time and the application cycle time.
A polarity reversal does not cause a high signal level nor does it destroy the outputs.
General electric features:
S Galvanic isolation through opto-couplers
S Current limited to max. 0.25 A
S Protection from:
– short-circuit
– overtemperature
– loss of grounding
S automatic shutdown in case of undervoltage
Siemens Automation Parts