Y070.302/EN Page 31
Operation instructions
SIPOS SEVEN: PROFITRON, HiMod
6
User management
6 User management
6 User management
6�1 General information
Many functions as well as parameterization can only be accessed using an access authorization
(4-digit code). This prevents unauthorized persons from changing parameters inadvertently or
advertently. Functions and parameters are grouped in user levels. Possible user levels are listed in
the following table:
User level
Authorization
required
(default setting)
Reading
parameters
Operate
actuator
Write
"simple"
parameters
Write
"expert"
parameters
1 Observer
No YES
2 Operator YES (0000)
YES YES
3 Supervisor YES (9044)
YES YES YES
4 Expert
YES (9044)
YES YES YES YES
Observer
Parameters can be displayed but not changed.
This user level has no special access authorization.
Operator
Parameters can be displayed but not changed.
Local actuator operation is possible.
For this user level, a 4-digit password is required. "0000" is the default setting. The user level
remains enabled by user level "0000" (refer to indication below).
Supervisor
Parameters can be displayed.
Parameterization of "simple" parameters.
Local actuator operation is possible.
For this user level, a 4-digit password is required. "9044“ is the default setting (see reference
below).
Expert
Like for "Supervisor" but in addition:
Parameterization of expert parameters.
LoadrmwarefromUSBashdrive,cloneactuator.
This user level is also protected by a 4-digit password. "9044“ is the default setting (see refer-
ence below).
If the password "0000” is assigned to a user level, this user level remains enabled, even if the
password “0000” has also been assigned for lower user levels. Renewed enabling is not required.
6�2 General procedure
Access to each user level, except for ‘Observer requires authorization, i.e. an individual password.
The default settings of these authorization passwords are listed in the previous chapter ‘General’.
The password can be changed at any time via the ‘Administration’ menu.
The following generally applies:
1. Once
Assign a password (4-digit code) to the desired user level:
‘Usermanagement’menu-->'Administration'Refertothefollowingchapter„6.3Assignpass-
word to user level/change password of a user level“
2. Prior to each session
Enable authorization for desired user level:
‘Usermanagement'-->'CurrentUser'.Refertothefollowingchapter„6.4Enableuserlevel“