EasyManua.ls Logo

Telit Wireless Solutions ME310G1 - AT#NIPDCONN - Open and Close a NIDD Connection

Telit Wireless Solutions ME310G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 1008 of 1039 2021-09-23
Not Subject to NDA
3.27.2. AT#NIPDCONN - Open and Close a NIDD Connection
This command allows the TE to open and close a NIDD connection. It is supported by
modules with NBIoT technology.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#NIPDCONN=<mode>
Parameter:
Name
Type
Default
Description
<mode>
integer
0
open/close the NIDD connection
Values:
0
:
close the NIDD connection
1
:
open the NIDD connection
AT#NIPDCONN?
Read command reports the status of the NIDD connection, in the format:
#NIPDCONN: <status>
<status> has the same meaning and values of <mode> parameter.
AT#NIPDCONN=?
Test command reports the supported range of values for parameter
<mode>.