EasyManua.ls Logo

Telit Wireless Solutions ME310G1 - AT#SI - Socket Info

Telit Wireless Solutions ME310G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 691 of 1039 2021-09-23
Not Subject to NDA
3.15.22. AT#SI - Socket Info
This command is used to get socket information.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
No
No
-
2
AT#SI[=<connId>]
Execution command returns information about all sockets data traffic.
Parameter:
Name
Type
Default
Description
<connId>
integer
NA
socket connection identifier. Refer to
Additional info sections to have
information about the use of the <connId>
parameter
Value:
1÷conMax
:
socket connection identifier. conMax value is
returned by test command
Additional info:
If the execution command is used with the <connId> socket
identifier, it returns data traffic information on the selected socket.
The format of the returned message is:
#SI: <connId>,<sent>,<received>,<buff_in>,<ack_waiting>
Name
Type
Default
Description
<sent>
integer
-
total amount (in bytes) of data
sent since the last time the
socket connection identified by
<connId> has been opened