ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 275 of 1039 2021-09-23
Not Subject to NDA
3.3.35. AT+CEDRXRDP - eDRX Read Dynamic Parameters
This command returns a message related to Extended Discontinuous Reception (eDRX).
3GPP TS 27.007
3GPP TS 24.008
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT+CEDRXRDP
Execution command returns the following message if eDRX is used for the
cell that the MS is currently registered to, in the format:
+CEDRXP:<AcTtype>[,<Req_eDRX>[,<NW_prov_eDRX>[,<PagTimeWindow>]]]
If the cell that the MS is currently registered to is not using eDRX,
<AcTtype>=0 is returned.
Additional info:
Here is the list of the meanings of the parameter returned by the
+CEDRXRDP command.
Name
Type
Default
Description
<AcTtype>
integer
0
type of access technology.
Values:
0
:
access technology is not using eDRX
2
:
see +CEDRXS.
4
:
see +CEDRXS.