EasyManua.ls Logo

Telit Wireless Solutions ME310G1 - ATS7 - Connection Completion Time-Out

Telit Wireless Solutions ME310G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 136 of 1039 2021-09-23
Not Subject to NDA
3.2.3.7. ATS7 - Connection Completion Time-Out
This set command specifies the amount of time that the DCE shall allow between either
answering a call (automatically or by the ATA command) or completion of signaling of
call addressing information to network (dialing), and establishment of a connection with
the remote DCE. If no connection is established during this time, the DCE disconnects
from the line and returns a result code indicating the cause of the disconnection.
ITU-T Recommendation V.25 ter
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Specific profile
No
-
2
ATS7=<tout>
Parameter:
Name
Type
Default
Description
<tout>
integer
60
defines time interval expressed in seconds
Value:
1÷255
:
available range
ATS7?
Read command returns the current value of S7 parameter.
The format of the numbers in output is always 3 digits, left-filled
with 0s.