3.8.10. AT#WAKE - Wake from Alarm Mode
Stop any alarm activity
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#WAKE=<opmode>
Execution command stops any eventually present alarm activity and, if the
module is in alarm mode, it exits the alarm mode and enters the normal
operating mode.
Parameter:
Name
Type
Default
Description
<opmode>
integer
0
operating
mode
Value:
0
:
normal operating mode; the module exits the alarm
mode and enters the normal operating mode, any
alarm activity is stopped (e.g. alarm tone playing)
and an OK result code is returned.
If #WAKE=0 command is issued after an alarm has been set with
+CALA command, but before the alarm has expired, it will answer
OK but have no effect.
AT#WAKE?
Read command returns the operating status of the device in the format:
#WAKE: <status>
where:
<status>