3.3.25. AT#CEERNET - Extended Numeric Error Report for Network Reject Cause
The command is related to extended numeric error report.
3GPP TS 24.008
3GPP TS 24.301
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#CEERNET
Execution command causes the TA to return a numeric code in the
intermediate response format:
#CEERNET: <code>
which should offer the user of the TA a report for the last mobility
management (MMGMM/EMM) or session management (SM/ESM)
procedure not accepted by the network.
Additional info:
17. The following error codes are valid for mobility
management (MM/GMM) or session management (SM), i.e.
for 2G and 3G networks.
18. In 4G network the <code>s meanings are included in tables
9.9.4.4.1 (for ESM causes) and 9.9.3.9.1 (for EMM cause) of
3GPP TS 24.301 Release 9.
Name
Type
Default
Description
<code>
integer
N/A
error code
Values: