EasyManua.ls Logo

Telit Wireless Solutions ME310G1 - Page 105

Telit Wireless Solutions ME310G1
1039 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 105 of 1039 2021-09-23
Not Subject to NDA
3
:
38400 bps
4
:
57600 bps
5
:
115200 bps
6
:
230400 bps
<N1>
integer
122
maximum frame size.
Value:
1÷1500
:
expressed in bytes
<T1>
integer
10
acknowledgement timer in units of
ten milliseconds
Value:
1÷255
:
in units of ten milliseconds
<N2>
integer
3
maximum number of re-
transmissions
Value:
0÷100
:
range of re-transmissions number
<T2>
integer
30
response timer for the multiplexer
control channel. T2 must be longer
than T1.
Value:
2÷255
:
in units of ten milliseconds
<T3>
integer
10
wake up response timer
Value:
1÷255
:
in seconds
<k>
integer
2
window size, for Advanced option with
Error-Recovery Mode
Value: