ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 524 of 1039 2021-09-23
Not Subject to NDA
AT#TEMPCFG= -273,-33,3,-35,-28,2,-30,80,0,78,90,3,88,528,3
OK
Rules 1 and 2 are respected.
zone
thr_clr
thr
action_in
Extreme low zone
-273
-33
3: emergency call only
Operate low zone
-35
-28
2: TX back off
Operate normal zone
-30
80
0: no mitigation
Operate up zone
78
90
3: emergency call only
Extreme up zone
88
528
3: emergency call only
AT#TEMPCFG=-273,-33,3,-35,-28,2,-30,80,0,79,90,3,88,528,3
+CME ERROR: operation not supported
Rule 1 is not respected:
(thr of Operate normal zone) - (thr_clr of Operate up zone) = 1 < 2
zone
thr_clr
thr
action_in
Extreme low zone
-273
-33
3: emergency call only
Operate low zone
-35
-28
2: TX back off
Operate normal zone
-30
80
0: no mitigation
Operate up zone
79
90
3: emergency call only
Extreme up zone
88
528
3: emergency call only
AT#TEMPCFG=-273,-33,3,-35,-28,2,-30,80,0,78,90,3,81,528,3
+CME ERROR: operation not supported
Rule 2 is not respected:
(thr_clr of Extreme up zone) - (thr of Operate normal zone) = 1 < 2
zone
thr_clr
thr
action_in
Extreme low zone
-273
-33
3: emergency call only
Operate low zone
-35
-28
2: TX back off
Operate normal zone
-30
80
0: no mitigation