<text_format>
integer
0
format of the <text> parameter
Values:
0
:
text
1
:
binary
<SMS_Num>
string
-
SMS Destination Number as string of
8-bit ASCII Characters. Max 20 chars.
International format is requested
(without '+'). This value is not
mandatory if Action = 2
<cid>
string
-
specifies a PDP context definition. To
know the range, see
+CGDCONT command
<IPProtocol>
integer
0
IP protocol used for socket
connection.
Values:
0
:
disable IP (both TCP and UDP) connection
1
:
TCP protocol
2
:
UDP protocol
<IPAddr:Port>
string
-
IPv4 server address with the socket
port. Number as string of 8bit ASCII
Characters. Max 20 chars. If
IPProtocol = 2 (UDP) local socket port
will be the same of server socket
port.
Additional info:
37. If <Action>=1 parameters <cid>, <IPProtocol>, and <IPAddr:Port> are
not mandatory
38. If <Action>=2 parameter <SMS_Num> is not mandatory
39. If <Action>=3, SMS has always more priority than IP connection
40. If <IPProtocol>=0 paremeter <IPAddr:Port> is not mandatory