ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 673 of 1039 2021-09-23
Not Subject to NDA
1
:
Set RAI to: "No further uplink or downlink data
transmission subsequent to this transmission"
2
:
Set RAI to: "Only a single downlink data transmission
and no further uplink data transmissions subsequent
to this transmission"
The maximum number of bytes to send is 1500 bytes; trying to send
more data will cause the surplus to be discarded and lost.
It is possible to use #SSEND only if the connection was opened by
#SD, else the ME is raising an error.
A byte corresponding to BS char (0x08) is treated with its
corresponding meaning; therefore previous byte will be cancelled
(and BS char itself will not be sent).
RAI (Release Assistance Indication) is supported in NB-IoT only,
otherwise is ignored.
AT#SSEND=?
Test command returns the range of supported values for parameter
<connId> and <Rai>.
Send data through socket number 2
AT#SSEND=2
>Test<CTRL-Z>
OK