ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev. 11 Page 84 of 1039 2021-09-23
Not Subject to NDA
mode (after +++ was entered), all URCs stored in the
buffer will be output
<keyp>
integer
0
keypad event
reporting
Value:
0
:
No keypad event reporting
<disp>
integer
0
display event
reporting
Value:
0
:
no display event reporting
<ind>
integer
0
indicator event
reporting
Values:
0
:
no indicator event reporting
2
:
indicator event reporting
<bfr>
integer
0
TA buffer clearing
Values:
0
:
TA buffer of unsolicited result codes is cleared when
<mode> 1..3 is entered
1
:
TA buffer of unsolicited result codes is flushed to the
TE when <mode> 1...3 is entered (OK response shall
be given before flushing the codes)
Sending of URCs in the case of key pressings or display changes
are currently not implemented.
After +CMER has been switched on with e.g. AT+CMER=2,0,0,2
command (i.e. <bfr> is 0), URCs for all registered indicators will be
issued only first time, if previous <mode> was 0, for backward
compatibility. Values shown by the indicators will be current