ELECTRICAL
4203780 First Edition 4-105
4
Figure 4-109
NOTES
• The low charge pressure switch is installed on the
control valve.
• Label all wires before disconnecting to ensure correct
installation.
3. Remove cover (1).
4. Disconnect wire connector (3).
5. Remove low charge pressure switch (2).
Installation Notes
• Install the low charge pressure switch by reversing
the order of removal.
• Install cover (1).
Mow Solenoids
See Figures 4-110 through 4-112.
Figure 4-110: Left Mow Solenoid
Figure 4-111: Right Mow Solenoid
Figure 4-112: Front Mow Solenoid
This procedure applies to the following solenoids:
• Left Mow Solenoid (1)
• Right Mow Solenoid (2)
• Front Mow Solenoid (3)
The left mow solenoid is located on the left deck valve.
The right mow solenoid is located on the right deck valve
The front mow solenoid is located on the front deck valve.
TN1921
2
3
1
TN1860
1
TN1868
2
TN1744
3