7. B-FV Setting Tool EO18-33030
7.6 Working with B-FV Setting Tool (V1.0.34)
7-92
■ D Mode, E Mode, I Mode, Z Mode and AUTO
D Mode, E Mode, I Mode, Z Mode and AUTO provide settings grouped in the Supply, Control,
Action, Label and Position Adjustment areas.
Note: “AUTO” is not available at present, and to be supported in future.
mm/inch/dot conversion process in Position Adjustment is as follows;
1. Input to the form in Setting Tool
Unit Value Setting condition
mm The value is adjustable in increments of ± 0.1 mm and rounded to
the 1st decimal place.
inch The value is adjustable in increments of ± 0.01 inch and rounded to
the 2nd decimal place.
dot The value is adjustable in increments of ± 1 dot and rounded to an
integer place.
2. Units Conversion process
1) When sending the value of the printer
The Setting value is transmitted as dot information to the printer.
Case Conversion process Calculation (Setting value = A) Rounding method
Case 1 mm => dot 203dpi A / 25.4 × 203 Rounded down to
an integer place
300dpi A / 25.4 × 300
Case 2 inch => dot 203dpi A × 203
300dpi A × 300