252
: If selected, the switch will send a Flash Operation
flash operation occurs
. The flash operations include firmware
upgrading, system resetting, config restoring and config saving.
reate/Delete If selected, the switch will send a VLAN Create/Delete trap when
VLAN is being created or deleted.
: If selected, the switch will send an IP Change trap when the
address of the switch is changed.
: If selected, the switch will send a Storm Control
broadcast, multicast or UL
rate exceeds the limit. You can
configure the limit on QoS→Bandwidth Control →
Control page.
: If selected, the switch will send a Bandwidth Control trap when
the
traffic rate of a port exceeds the limit. You can configure the limit
on QoS→Bandwidth Control→Rate limit page.
If selected, the switch will send an LLDP trap when t
LLDP changes.
: If selected, the switch will send a MAC Address Table
the MAC address table has any changes.
If selected, the switch will send a Loopback Detection
the status of loopback detection changes.
: If selected, the switch will send a Spanning Tree trap when t
status of STP on the port changes.
: If selected, the switch will send a Port Access
users try to log on to the web management page
that have no authority. You can configure the access control pol
on System→Access Security→Access Control page.
-MAC Binding: If selected, the switch will send an IP-MAC Binding
trap when it
receives a packet from the host that does not match the rules in
IP-MAC binding table. You can configure the IP-MAC Binding
policy on Network Security→IP-MAC Binding page.
: If selected, the switch will send an IP Duplicate trap when
host uses the switch's IP address.
: If selected, the switch will send a DHCP Filter
receives a DHCP packet from an untrusted port.
DM Temperature: If selected, the switch will send a DDM Temperature trap when t
value of DDM temperature exceeds the threshold.
If selected, the switch will send a DDM Voltage trap when t
value of DDM voltage exceeds the threshold.
Bias Current: If selected, the switch will send a DDM Bias Current trap when t
value of DDM bias current exceeds the threshold.
If selected, the switch will send a DDM Tx Power trap when t
value of DDM Tx power exceeds the threshold.