Operation40024/A1
Winterthur Gas & Diesel Ltd.
4/ 4
2.2 Replace Defective CCM-20
Note: It is recommended to make a software back-up from the LDU-20. This will
make sure that the correct configuration is loaded. For more data, speak
to or send a message to Winterthur Gas & Diesel Ltd.
1) Stop the engine.
2) Disconnect the power supply to the defective CCM-20 on the related cylinder.
3) Remove the defective CCM-20.
4) Install the new CCM-20.
5) Connect the power supply to the new CCM-20.
6) After a reboot of the new CCM-20, the ECS activates a software download.
Note: You can monitor the software download on the LDU-20 at the local
control panel.
7) Start the engine. The engine does an air run to find the crank angle for the new
CCM-20.
Note: After the air run, the engine will do a standard start.
2.3 Replace Defective MCM11
Note: It is recommended to make a software back-up from the LDU20. This will
make sure that the correct configuration is loaded. For more data, speak
to or send a message to Winterthur Gas & Diesel Ltd.
1) Stop the engine.
2) Disconnect the power supply to the MCM11.
3) Remove the defective MCM11.
4) Install the new MCM11.
5) Connect the power supply to the new MCM11.
6) After a reboot of the new MCM11, the ECS activates a software download.
Note: You can monitor the software download on the LDU20 at the local
control panel.
7) Start the engine at the RCS. The engine will do a standard start.
2.4 Replace Defective IOM-10
Note: It is recommended to make a software back-up from the LDU-20. This will
make sure that the correct configuration is loaded. For more data, speak
to or send a message to Winterthur Gas & Diesel Ltd.
1) Stop the engine.
2) Disconnect the power supply to the IOM-10.
3) Remove the defective IOM-10.
4) Install the new IOM-10.
5) Connect the power supply to the new IOM-10.
6) After a reboot of the new IOM-10, the ECS activates a software download.
Note: You can monitor the software download on the LDU20 at the local
control panel.
7) Start the engine at the RCS. The engine will do a standard start.
ECS Modules Replacement
201611