5.11 S: Elevator Parameters
272 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Figure 5.51 Operation Sequence Example for Leveling Distance Control
S5-10: Stopping Method Selection
Selects the stopping method.
Setting 0: Disable
Setting 1: Direct Landing
Setting 2: Leveling Distance Control
S5-11: Deceleration Distance
Sets the deceleration distance when Stop Distance Control is enabled. Refer to Direct Landing on page 270 for details.
S5-12: Stop Distance
Sets the stopping distance when Stop Distance Control is enabled. Refer to Direct Landing on page 270 and Leveling
Distance Control on page 271 for details.
S5-13: Direct Landing Minimum Speed Level
Sets the speed level for the start of Direct Landing. Direct Landing is disabled if the starting speed for Direct Landing is
less than the maximum output speed multiplied by this parameter (E1-04 × S5-13).
<1> Area S is the stopping distance (S5-12) from the point at which leveling operation is complete to when the car arrives at the designated
floor.
No. Parameter Name Setting Range Default
S5-10 Stopping Method Selection 0 to 2 0
No. Parameter Name Setting Range Default
S5-11
<1> The setting range becomes 0.00 to 650.00 inches when the length units are set for inches (o1-12 = 1).
Deceleration Distance 0 to 32767 mm
<1>
0 mm
No. Parameter Name Setting Range Default
S5-12
<1> The setting range becomes 0.00 to 393.00 inches when the length units are set for inches (o1-12 = 1).
Stop Distance 0 to 10000 mm
<1>
0 mm
No. Parameter Name Setting Range Default
S5-13 Direct Landing Minimum Speed Level 0 to 100% 20%
Operation
Speed
Time
ON OFF
OFFOFF
OFF
ON
ON
ON
Run Command Delay Time (S1-10)
Brake Release Delay Time
Brake Close
Delay Time
ON
Zero Speed
at Start
(S1-06)
Zero Speed
at Stop
(S1-07)
Output Contactor Open
Delay Time (S1-11)
Run Command
(Forward [Up] / Reverse [Down])
H2- = 53 (Not Zero Speed)
H2- = 51
(
Output Contactor Control
)
H1- = 56
(
Motor Contactor Feedback
)
H2- = 50 (Brake Control)
S
<1>
SIEP_C710616_38F_5_0.book 272 ージ 015年11月9日 月曜日 午後3時36分