B.3 Parameter Table
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 401
■ d6: Field Forcing
d1-26
(2C8H)
Leveling Speed
Sets leveling speed reference when d1-18 = 1 or 2.
Default: 8.00%
<6>
Min: 0.00%
Max: 100.00%
<6>
184
d1-27
(2C9H)
Motor 2 Speed Reference
Sets the speed reference for motor 2.
Note:
1. If set to 0.00, the drive will control motor 1 instead.
2. When using motor 2, be sure that the accel/decel times are set in parameters C1-12 and
C1-13.
Default: 0.00 Hz
Min: 0.00 Hz
Max: 200.00 Hz
185
d1-28
(2CAH)
Leveling Speed Detection Level
Used when d1-18 = 0 or 3. If the speed reference selected is lower than d1-28, then the drive
uses the leveling speed as the speed reference.
Default: 0.0%
Min: 0.0%
Max: 100.0%
185
d1-29
(2CBH)
Inspection Speed Detection Level
Used when d1-18 = 0 or 3. If the speed reference selected is higher than d1-28 but lower or
equal to d1-29, then the drive uses inspection speed as the speed reference.
Default: 0.0%
Min: 0.0%
Max: 100.0%
185
<6> Setting ranges and defaults vary by the setting units determined by parameter o1-03.
Refer to Defaults and Setting Ranges by Display Unit Selection (o1-03) on page 442.
No.(Addr.) Name Description Setting Page
d6-03
(2A2H)
Field Forcing Selection
0: Disabled
1: Enabled
Default: 0
Min: 0
Max: 1
186
d6-06
(2A5H)
Field Forcing Limit
Sets the upper limit of the excitation current command during magnetic field forcing. A setting
of 100% is equal to motor no-load current. Disabled only during DC Injection Braking.
Default: 400%
Min: 100%
Max: 400%
186