D.3 UL and CSA Standards
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 483
Note: Use crimp insulated terminals or insulated tubing for wiring these connections. Wires should have a continuous maximum
allowable temperature of 75°C (167°F) 600 V UL approved vinyl sheathed insulation. Ambient temperature should not exceed
40°C (104°F).
Table D.5 Wire Gauge and Torque Specifications (Three-Phase 400 V Class)
20215
<2>
R/L1, S/L2, T/L3 3/0 × 2P 3/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 3/0 × 2P 3/0 to 300
–, +1 – 3/0 to 300
+3 – 2 to 300 M10
18 to 23
(159 to 204)
33 to 300M12
32 to 40
(283 to 354)
20283
<2>
R/L1, S/L2, T/L3 4/0 × 2P 3/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 3/0 × 2P 3/0 to 300
–, +1 – 3/0 to 300
+3 – 3/0 to 300 M10
18 to 23
(159 to 204)
22 to 300M12
32 to 40
(283 to 354)
20346
<2>
R/L1, S/L2, T/L3 250 × 2P 4/0 to 600
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 4/0 × 2P 4/0 to 600
–, +1 – 250 to 600
+3 – 3/0 to 600 M10
18 to 23
(159 to 204)
11 to 350M12
32 to 40
(283 to 354)
20415
<2>
R/L1, S/L2, T/L3 350 × 2P 250 to 600
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 300 × 2P 300 to 600
–, +1 – 300 to 600
+3 – 3/0 to 600 M10
18 to 23
(159 to 204)
11 to 350M12
32 to 40
(283 to 354)
<1> When an EMC filter is installed, additional measures must be taken in order to comply with IEC/EN 61800-5-1. Refer to EMC Filter
Installation on page 477.
<2> Drive models CIMR-LU20085 to 20415 require the use of closed-loop crimp terminals for UL/cUL compliance. Use only the tools
recommended by the terminal manufacturer for crimping.
Model
CIMR-LU
Terminal
Recommended Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Screw
Size
Tightening Torque
Nm (lb.in.)
40005
40006
40007
R/L1, S/L2, T/L3 14 14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3 14 14 to 10
–, +1, +2 – 14 to 10
B1, B2 – 14 to 10
10 14 to 10
40009
R/L1, S/L2, T/L3 12 14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3 14 14 to 10
–, +1, +2 – 14 to 10
B1, B2 – 14 to 10
10 14 to 10
40015
R/L1, S/L2, T/L3 10 12 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3 10 12 to 6
–, +1, +2 – 12 to 6
B1, B2 – 12 to 10
10 14 to 10 M5
2.0 to 2.5
(17.7 to 22.1)
40018
R/L1, S/L2, T/L3 10 10 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3 10 10 to 6
–, +1, +2 – 12 to 6
B1, B2 – 12 to 10
10 12 to 10 M5
2.0 to 2.5
(17.7 to 22.1)
Model
CIMR-LU
Terminal
Recommended Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Screw
Size
Tightening Torque
Nm (lb.in.)