9.1 Alarm Displays and Troubleshooting
9-3
9
A.04
A.04: Parameter Setting Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs ALM Output
ALO1 ALO2 ALO3
OFF OFF OFF OFF
Cause Remedy
A An out-of-range parameter was previously set
or loaded.
• Reset all parameters in range.
• Otherwise, re-load correct parameter.
B Circuit board (1PWB) is defective. Replace the SERVOPACK.
C NS115 is defective. Replace the NS115.
At power ON
A, B, C