4 MECHATROLINK-II Communications
4.3.23 Servo OFF (SV_OFF: 32H)
4-30
4.3.23 Servo OFF (SV_OFF: 32H)
Byte SV_OFF Description
Command Response
1 32H 32H Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2 ALARM Processing time Follow settings
from Pn506 to
Pn508.
Subcommand Can be used.
3STATUS• The SERVOPACK changes to Servo OFF.
• Can be used during phases 2 and 3.
• During phase 1, a MECHATROLINK-II command warning (A.95) will occur
and the command will be ignored.
4
5 MONITOR1
6
7
8
9 MONITOR2
10
11
12
13 SEL_MON 1/2 SEL_MON 1/2
14 IO_MON
15
16 WDT RWDT
17 For
subcommands
use. Refer to
4.4 Subcom-
mands.
For
subcommands
use. Refer to
4.4 Subcom-
mands.
18
19
20
21
22
23
24
25
26
27
28
29