Troubleshooting
709
Parameters
Permitted Values
Default
static.syslog.ftp.post_mode
1 or 2
1
Description:
Configures whether the log files on the provisioning server are overwritten or appended.
1-Post Append (not applicable to TFTP Server)
2-Post Stor
If it is set to 1 (Post Append), the log files on the provisioning server are appended.
If it is set to 2 (Post Stor), the log files on the provisioning server are overwritten.
Note: It works only if the value of the parameter “static.syslog.mode” is set to 2 (FTP/TFTP
Server). If you change this parameter, the IP phone will reboot to make the change take
effect.
Web User Interface:
Settings->Configuration->Post Mode
Phone User Interface:
None
static.syslog.ftp.max_logfile
Integer from 200
to 65535
512
Description:
Configures the maximum size of the log files (in KB) can be stored on the provisioning
server.
Example:
static.syslog.ftp.max_logfile = 511
Note: It works only if the value of the parameter “static.syslog.mode” is set to 2 (FTP/TFTP
Server). If you change this parameter, the IP phone will reboot to make the change take
effect.
Web User Interface:
Settings->Configuration->Append Limit Size
Phone User Interface:
None
static.syslog.ftp.append_limit_mode
1 or 2
1
Description:
Configures the behavior when log file on the provisioning server reaches the max size.
1-Append Delete