Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Not selected / uint32
When bit 0 of parameter 28.21 Constant frequency function
is 0 (Separate), selects a source that activates constant
frequency 3.
When bit 0 of parameter 28.21 Constant frequency function
is 1 (Packed), this parameter and parameters 28.22
Constant frequency sel1 and 28.23 Constant frequency
sel2 select three sources that are used to activate constant
frequencies.
See table at parameter 28.22 Constant frequency sel1.
For the selections, see parameter 28.22 Constant
frequency sel1.
Constant frequency
sel3
28.24
0.00 Hz / real32Defines constant frequency 1 (the frequency the motor will
turn when constant frequency 1 is selected).
Constant frequency 128.26
- / -
Constant frequency 1. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
0.00 Hz / real32Defines constant frequency 2.Constant frequency 228.27
- / -
Constant frequency 2. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
0.00 Hz / real32Defines constant frequency 3.Constant frequency 328.28
- / -
Constant frequency 3. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
0.00 Hz / real32Defines constant frequency 4.Constant frequency 428.29
- / -
Constant frequency 4. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
0.00 Hz / real32Defines constant frequency 5.Constant frequency 528.30
- / -
Constant frequency 5. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
0.00 Hz / real32Defines constant frequency 6.Constant frequency 628.31
- / -
Constant frequency 6. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
0.00 Hz / real32Defines constant frequency 7.Constant frequency 728.32
- / -
Constant frequency 7. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
- / real32Defines a safe frequency reference value that is used with
supervision functions such as
12.3 AI supervision function
49.5 Communication loss action
50.2 FBA A comm loss func
50.32 FBA B comm loss func
58.14 Communication loss action.
Frequency ref safe28.41
- / -
Safe frequency reference. For scaling, see parameter 46.2.
-598.00 ... 598.00 Hz
- / uint16Enables/disables the critical frequencies function. Also
determines whether the specified ranges are effective in
both rotating directions or not.
See also section Critical speeds/frequencies (page 48).
Critical frequency
function
28.51
1 = Enable: Critical frequencies enabled.
0 = Disable: Critical frequencies disabled.
Enableb0