Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
0 / uint16Displays (in integer format) the data to be sent to the
external controller as word 1 of data set 2.
If no data has been preselected by 61.45 Data set 2 data
1 selection, the value to be sent can be written directly into
this parameter.
Data set 2 data 1
value
61.95
- / -Data to be sent as word 1 of data set 2.0...65535
0 / uint16Displays (in integer format) the data to be sent to the
external controller as word 2 of data set 2.
If no data has been preselected by 61.46 Data set 2 data
2 selection, the value to be sent can be written directly into
this parameter.
Data set 2 data 2
value
61.96
- / -Data to be sent as word 2 of data set 2.0...65535
0 / uint16Displays (in integer format) the data to be sent to the
external controller as word 3 of data set 2.
If no data has been preselected by 61.47 Data set 2 data
3 selection, the value to be sent can be written directly into
this parameter.
Data set 2 data 3
value
61.97
- / -Data to be sent as word 3 of data set 2.0...65535
…………
0 / uint16Displays (in integer format) the data to be sent to the
external controller as word 3 of data set 4.
If no data has been selected by 61.50 Data set 4 data 3
selection, the value to be sent can be written directly into
this parameter.
Data set 4 data 3
value
61.100
- / -Data to be sent as word 3 of data set 4.0...65535
- / uint16Displays (in integer format) the data to be sent to the
external controller as word 1 of data set 11.
If no data has been preselected by 61.51 Data set 11 data
1 selection, the value to be sent can be written directly into
this parameter.
Data set 11 data 1
value
61.101
- / -Data to be sent as word 1 of data set 11.0...65535
- / uint16Displays (in integer format) the data to be sent to the
external controller as word 2 of data set 11.
If no data has been preselected by 61.52 Data set 11 data
2 selection, the value to be sent can be written directly into
this parameter.
Data set 11 data 2
value
61.102
- / -Data to be sent as word 2 of data set 11.0...65535
- / uint16Displays (in integer format) the data to be sent to the
external controller as word 3 of data set 11.
If no data has been selected by 61.53 Data set 11 data 3
selection, the value to be sent can be written directly into
this parameter.
Data set 11 data 3
value
61.103
- / -Data to be sent as word 3 of data set 11.0...65535
- / uint16Displays (in integer format) the data to be sent to the
external controller as word 1 of data set 13.
If no data has been selected by 61.54 Data set 13 data 1
selection, the value to be sent can be written directly into
this parameter.
Data set 13 data 1
value
61.104
Parameters 459