Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / -Initial value for position counter.-2147483.648 ...
2147483.647
Pos counter init value
/ uint32
Selects the source of the initial position value. When the
source selected by 90.67 Pos counter init cmd source
activates, the value selected in this parameter is assumed
to be the position of the load (in decimal format).
Pos counter init value
source
90.66
00.Zero
1
Parameter 90.65 Pos counter init value.
Pos counter init value
See Terms and abbreviations (page 132).
Other
Not selected / uint32Selects a digital source (for example, a limit switch
connected to a digital input) that initializes the position
counter. When the digital source activates, the value
selected by 90.66 Pos counter init value source is assumed
to be the position of the load.
Note: Position counter initialization can be prevented by
parameter 90.68 Disable pos counter initialization.
Pos counter init cmd
source
90.67
00Not selected
11Selected
2
Digital input DI1 (10.2 DI delayed status, bit 0).
DI1
3
Digital input DI2 (10.2 DI delayed status, bit 1).
DI2
4
Digital input DI3 (10.2 DI delayed status, bit 2).
DI3
5
Digital input DI4 (10.2 DI delayed status, bit 3).
DI4
6
Digital input DI5 (10.2 DI delayed status, bit 4).
DI5
7
Digital input DI6 (10.2 DI delayed status, bit 5).
DI6
10
Digital input/output DIO1 (11.2 DIO delayed status, bit 0).
DIO1
11
Digital input/output DIO2 (11.2 DIO delayed status, bit 1).
DIO2
Source selection See Terms and abbreviations (page 132).
Other [bit]
Not selected / uint32Selects a source that prevents the initialization of the
position counter.
Disable pos counter
initialization
90.68
00Not selected
11Selected
2
Digital input DI1 (10.2 DI delayed status, bit 0).
DI1
3
Digital input DI2 (10.2 DI delayed status, bit 1).
DI2
4
Digital input DI3 (10.2 DI delayed status, bit 2).
DI3
5
Digital input DI4 (10.2 DI delayed status, bit 3).
DI4
6
Digital input DI5 (10.2 DI delayed status, bit 4).
DI5
7
Digital input DI6 (10.2 DI delayed status, bit 5).
DI6
10
Digital input/output DIO1 (11.2 DIO delayed status, bit 0).
DIO1
11
Digital input/output DIO2 (11.2 DIO delayed status, bit 1).
DIO2
Source selection See Terms and abbreviations (page 132).
Other [bit]
480 Parameters