What to doCause
Event name /
Aux. code
Code
(hex)
Measure insulation resistances of motor
cables and motor.
Contact your local ABB representative.
Check AC fuses.IGBT supply unit has detected an earth
fault.
Earth leakage2E01
Check for earth leakages.
Check supply cabling.
Check power modules.
Check there are no power factor
correction capacitors or surge absorbers
in supply cable.
If no earth fault can be detected, contact
your local ABB representative.
Check that the speed points of the curve
(defined by 29.70…29.79) are in
increasing order.
Parametrization of the speed/torque
limitation curve (in the DC voltage
reference chain) are inconsistent.
Invalid voltage
chain
datapoints
3000
Check input power line fuses.Intermediate circuit DC voltage is
oscillating due to missing input power
line phase or blown fuse.
Supply phase
loss
3130
Check for loose power cable
connections.
Check for input power supply imbalance.
Contact your local ABB representative.No acknowledgement received from
charge relay.
Charge relay
lost
3180
Wiring or earth
fault
3181
1. Switch off the protection in
parameter 31.23.
1. The drive hardware is supplied from
a common DC bus.
2. Incorrect input power and motor
cable connection (i.e. input power
2. Check the power connections.
Check the input fuses.
cable is connected to the motor
connection).
3. Check there are no power factor
correction capacitors or surge
absorbers in motor cable.
3. Drive has detected load unbalance
typically due to earth fault in motor
or motor cable.
Check for an earth fault in motor or
motor cables by measuring the
insulation resistances of motor and
motor cable.
Try running the motor in scalar
control mode if allowed. (See
parameter 99.4 Motor control
mode.)
Check that overvoltage control is on
(parameter 30.30 Overvoltage control).
Excessive intermediate circuit DC
voltage.
DC link
overvoltage
3210
Check that the supply voltage matches
the nominal input voltage of the drive.
Check the supply line for static or
transient overvoltage.
Check brake chopper and resistor (if
present).
Check deceleration time.
Use coast-to-stop function (if applicable).
Retrofit drive with brake chopper and
brake resistor.
With parallel-connected modules, check
the auxiliary code (format XXXY YYZZ).
Fault tracing 543