KNX control elements and application parameters
Operation of "RGBW" control element“
Product manual 2CKA00xx73xxxxx
130
Temperature/brightness objects (Hue): If no separate channels are available (e.g.
Philips Hue), activation takes place via the colour temperature and brightness. The
communication objects are named the same for both types of activation; however,
different values are sent (either brightness and colour temperature or Cold White and
Warm White).
10.5.5 Brightness change [%]
Options: Setting option from 1 - 20
The parameter is used to set the number of steps (in percent) for dimming. The brightness
change takes place when the slider is released.
10.5.6 Telegram is repeated every [sec.]:
Options: Setting option from 0.25 - 1.25 seconds
The parameter is used to specify the space of time between two telegrams.
10.5.7 Enable 1-bit communication object "Disable"
Options: Deactivated
Activated
There is the option of temporarily disabling the function via an additional communication object
"Disable".