Restriction System Option Description
Ignore site code If enabled, the access system will ignore site codes. By ignoring the site
code, you only add the card number and increase the card users on the
system from 100 to 2,500.
Card Formats Click the Edit button to select the card formats that will be allowed on this
panel.
See Supported card readers and card formats on page286 for details of
currently supported card readers and card formats.
Note: Selecting Wiegand enables all Wiegand card formats.
Web Only Door Mode Set Select the required user identification to unlock door when area is set.
Options are Default, Card and PIN, Card Or PIN.
Web Only Door Mode
Unset
Select the required user identification to unlock door when area is unset.
Options are Default, Card and PIN, Card Or PIN.
Override Reader
Profile
If enabled, Reader LEDs indicate setting confirmation and Card+PIN
request.
Engineer
Engineer
Restore
(Impact only if Region "UK" is chosen): If this option is enabled, then the
engineer has to restore the confirmed alarms. This option works together
with the function "Confirmation".
Engineer Exit If enabled, the engineer is allowed to leave Full Engineer mode with alerts
active.
Allow Engineer Enable this feature to ensure that the engineer can only access the system if
the user allows it.
If disabled, ENABLE ENGINEER menu option on keypad is not available.
Note: Only available if Security Grade is ‘Unrestricted’. For Grade 2/3, user
control of engineer access to system is always available.
Allow
Manufacturer
Enable this feature to ensure that the engineer can only access the system if
the user allows it.
If disabled, ENABLE MANUFACTURER menu option on keypad is not
available.
Note: Only available if Security Grade is ‘Unrestricted’. For Grade 2/3, user
control of engineer access to system is always available if user type is
‘Manager’.