7. Select an Event Profile from the dropdown menu. To customise how events are transmitted on
an ATS, see Configuring Event Profiles on page233.
8. Select a Command Profile from the dropdown menu. To customise the commands enabled for
an RCT to control a panel, see Configuring Command Profiles on page235.
9. Complete the ATS Faults fields as shown in the table below.
ATS
Polling
Timeout
This field is automatically calculated by adding the values of the Active Polling
Timeout column in the Event Sequence Table, that is, for all ATPs in an ATS.
You can manually overwrite this field. For example, CAT 2 [Modem] has an
Active Polling Timeout of 24 hours 10 minutes (87000 seconds). To allow a
shorter reaction time, enter a lower value.
ATS Event
Timeout
The amount of time after an event has been raised and not successfully
transmitted before the ATS gives up. Default: 300 seconds.
Generate
FTC
Select whether the system generates a FTC on an ATS event timeout.
ATS/ATP
Fault
Events
Select to generate network events when this ATS or any other ATS on the
system goes up or down. Default setting is off.
Re-queue
Events
Select this to re-queue events after an ATS Timeout.
Re-queue
Event
Delay
Delay after an ATS Event Timeout before the re-queued event is attempted
again. Default: 300 seconds.
Re-queue
Event
Duration
Amount of time that the event will be re-queued before the event is deleted.
Default: 86400 seconds.
Log ATS
Faults
Select this to add ATS faults to the system log.
10. Click the Edit Installation Details button to complete the settings to identify the panel to the RCT
operator. See Edit Installation Details on page231.
11. Click Save and Back to return to the ATS Configuration page. The new ATS displays in the
Configured ATS table.
12. For multiple ATPs, you can use the up and down arrows in the Event Sequence Table to reorder
the ATP sequence.
NOTICE: The ATS Registration ID is automatically generated for an ATS. It uniquely identifies the
panel to the RCT. If you do not know the SPT Account Code, you can commission the panel using
this ATS Registration ID. The CMS operator must also enter this ATS Registration ID at the RCT
(for example, SPC Com XT). See the SPC Com XT Installation & Configuration Manual.
See also
ATS Category Timings on page292
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser