ATP Interface
EN50136
ATS
Category
Select the EN50136 ATS Category (SP1-SP6, DP1-DP4). For a description of categories, see
ATS Category Timings on page292.
Primary
Interface
Select the Primary Interface to apply to the primary communications path from the following:
l
Ethernet
l
GPRS: Modem 1
l
GPRS: Modem 2
l
Dial Up Internet: Modem 1
l
Dial Up Internet: Modem 2
Backup
Interface
For a Dual Path ATS, select the Backup Interface to use for the backup communications path
from the following:
l
Ethernet
l
GPRS: Modem 1
l
GPRS: Modem 2
l
Dial Up Internet: Modem 1
l
Dial Up Internet: Modem 2
15.11.2.3 Configuring an EN50136-1 ATS or Custom ATS
An ATS comprises an alarm panel, network paths and an RCT (for example, SPC Com XT). It
combines one or multiple paths between an SPC panel and an RCT. You can add up to 10 ATPs to
an ATS.
NOTICE:For an EN50136-1 ATS, the ATS set up sequence starts with configuring an ATP for
an ATS. This provides you with a quick set up feature. See Quick Start ATP Configuration for
EN50136 ATS on page216.
1. To configure an ATS, go to Communications > FlexC > FlexC ATS.
2. Choose from one of the following options:
l
Add Single Path ATS
l
Add Dual Path ATS
l
Add Dual Path Dual Server ATS
l
Add Custom ATS
3. For an EN50136 ATS, you must configure the settings on the ATP Configuration - EN50136
page first. See Quick Start ATP Configuration for EN50136 ATS on page216.
4. The ATS Configuration page displays. An EN50136-1 ATS will display a primary or primary
and backup ATP in the Event Sequence Table.
5. Enter an ATS Name to identify the ATS. If you do not enter a value, the ATS name defaults to
ATS 1, ATS 2, etc.
6. To add 1 primary and up to 9 backup ATPs to an ATS, click Add ATP to FlexC RCT (see Add
ATP to FlexC RCT on page220) or click Add ATP to Analog ARC (see Add ATP to Analog
ARC on page229).
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 218 I-200572
08.12.2023