Test Call
Mode (Active
ATP)
Select the mode for sending test calls when the ATP is the active ATP.
l
Test calls Disabled
l
Test call every 10 minutes
l
Test call every 1 hour
l
Test call every 4 hours
l
Test call every 24 hours
l
Test call every 48 hours
l
Test call every 7 days
l
Test call every 30 days
Encryption (256-bit AES with CBC)
Encryption
Key Mode
Select how the encryption gets updated.
l
Auto Encryption
l
Auto Encryption with Updates
l
Fixed Encryption
Note: Auto Encryption uses the default key and updates it once. Auto
Encryption with Updates changes the encryption key every 50,000
messages or once per week, whichever comes first.
Encryption
Password
Optional password used to provide increased security during initial ATP
commissioning. The password must be entered at the SPT or RCT
independently.
Reset
Encryption
Reset the Encryption Key and password to the default values.
ATP Profiles
Event Profile Select the Event Profile which defines how and which events are transmitted
on this ATS.
l
Use ATS Setting
l
Default Event Profile
l
All events
Command
Profile
Select the Command Profile which defines the commands that are allowed
on this ATS.
l
Use ATS Setting
l
Default Command Profile
l
Custom Command Profile
ATP Faults
ATP
Monitoring
Fault
Select to generate an ATP fault if the ATP monitoring fails or an event fails to
transmit on the ATP.