Timer Description Default
Fail To Set
FAIL TO SET
Number of seconds to display fail to set message on keypads (0
until valid PIN is entered). (0–999 seconds)
10 sec.
Strobe on Fullset
FULLSET STROBE
Activates the strobe on the external bell momentarily to indicate
a full set condition. (0–10 seconds)
0 sec.
DELAYUNSETBUZZERTIME 1 sec
Alarm
Double Knock
DKNOCK DELAY
The maximum delay between activation’s of zones with the
double attribute, which will cause an alarm. (1–99 seconds)
10sec.
Soak
SOAK DAYS
The number of days a zone remains under soak test before it
automatically returns to normal operation. (1–99 days)
14 days
Seismic Test Interval
SEISMIC AUTOTEST
The average period between seismic sensor automatic tests.
(12–240 hours)
Note: To enable automatic testing, the Automatic Sensor
Test attribute must be enabled for a seismic zone.
168 hours
Seismic Test Duration
SEISMIC TEST DUR
Maximum time (in seconds) that a seismic sensor takes to
trigger an alarm in response to the 'Seismic Test' output. (3–120
seconds)
30 sec.
Auto Restore Delay Time to delay auto restore after zone state returns to normal.
(0–9999 seconds)
0 sec.
Lockout Post Alarm
LOCKOUT POST ALARM
The duration of time after an alarm before the user can gain
access. (1–120 minutes)
30 min.
Access Time The duration of time the system can be accessed by an alarm
access user after the Lockout Time has elapsed. (10–240
minutes)
120 min
External Bell Strobe
STROBE TIME
Duration that the strobe output will be active when an alarm is
activated. (1–999 minutes; 0=indefinitely)
15min.
Alerts
Mains Delay
MAINS SIG DELAY
The time after a mains fault has been detected before an alert is
activated by the system. (0–60 minutes)
0min.
RFJamming Delay The time after RF Jamming has been detected before an alert is
activated by the system. (0–999 seconds)
0min.
Engineer
Engineer Access
ENGINEER ACCESS
The timer for the Engineer access starts as soon as the user
enables the Engineer Access. (0–999 minutes; 0 indicates no
time limitation for system access)
0 min.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the keypad
© Vanderbilt 2023 73 I-200572