Setting Description
Function Keys (in idle state)
Panic Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing the 2
soft keys together.
Verification If you assign a verification zone to the keypad, when a panic alarm is triggered by pressing 2 soft
keys together or by entering a duress code, audio and video events are activated.
Visual Indications
Backlight Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always off.
Indicators Enable or disable the LED’s on the keypad.
Setting state Select if setting state should be indicated in idle mode.
Audible Indications
Buzzer Enable or disable the buzzer on the keypad.
Partset
Buzzer
Enable or disable buzzer during exit time on Partset.
Keypress Select if the speaker volume for the key presses should be activated.
Deactivation
Calendar Select if the keypad should be limited by calendar. See Calendars on page197.
Mapping gate Select if keypad should be limited by a mapping gate.
Keyswitch Select if keypad should be limited by a keyswitch.
PACE Entry Tick this box to disable the keys on the keypad during the entry time when a PACE is configured
on the keypad.
Areas
Location Select the secured area where the keypad is located.
Areas Select which areas can be controlled through keypad.
Options
Delay Fullset Select to configure a delayed set across all keypads. The location of the keypad is ignored and
all areas will perform a full exit time count down.
NOTICE: An area should be assigned to a keypad only if the keypad is inside the assigned area,
and if an entry/exit route is defined. If an area is assigned, when the particular area is set or
unset then entry and exit timers are used (if configured). Other features related to entry/exit
routes also become available. If no area is assigned, the area is set or unset immediately and
other entry/exit features are not available.
Comfort Keypad Settings
Configure the following settings for the comfort keypad.
SPC42/52/53/63 – Installation & Configuration Manual Engineer programming via the keypad
© Vanderbilt 2023 80 I-200572