Setting Description
Description Enter a unique description to identify the keypad.
Function Keys (in idle state)
Panic Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing F1
and F2 soft keys together.
Fire Enable to allow fire alarm to be activated by pressing F2 and F3 soft keys together.
Medical Enable to allow medical alarm to be activated by pressing F3 and F4 soft keys together.
Fullset Enable to allow Fullset to be activated by pressing F2 key twice.
Partset A Enable to allow Partset A to be activated by pressing F3 key twice.
Partset B Enable to allow Partset B to be activated by pressing F4 key twice.
Verification If you assign a verification zone to the comfort keypad, when a Medical, Panic or Fire event is
triggered, or if a user enters a duress code, then audio and video events are activated.
Visual indications
Backlight Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always
off.
Backlight Level Select the intensity of illumination of the backlight. Range 1–8 (High).
Indicators Enable or disable the LED’s on the keypad.
Setting state Enable if setting state should be indicated in idle mode. (LED)
Logo Enable if logo should be visible in idle mode.
Analog Clock Select position of clock if visible in idle mode. Options are Left Aligned, Center Aligned, Right
Aligned or Disabled.
Emergency Enable if Panic, Fire and Medical function keys should be indicated in the LCD display.
Direct Set Enable if Fullset/Partset function keys should be indicated in the LCD display.
Audible indications
Alarms Select speaker volume for alarm indications or disable sound.
Entry/Exit Range is 0–7 (max volume).
Chime Select speaker volume for entry and exit indications or disable sound.
Keypress Range is 0–7 (max volume).
Voice
Annunciation
Select speaker volume for chime or disable sound.
Partset Buzzer Range is 0–7 (max volume).
Deactivation
Calendar Select if the keypad should be limited by calendar.
Mapping gate Select if keypad should be limited by a mapping gate.