Configuring a VLL Service with CLI
Page 196 7750 SR OS Services Guide
The following example displays the configuration:
*A:ALA-T-PE1>config>service>epipe# info
----------------------------------------------
endpoint "x" create
exit
endpoint "y" create
exit
sap 1/1/1:100 endpoint "x" create
exit
spoke-sdp 1:100 endpoint "y" create
precedence primary
revert-time 0
exit
spoke-sdp 4:400 endpoint "y" create
precedence 0
exit
no shutdown
----------------------------------------------
*A:ALA-T-PE1>config>service>epipe#
T-PE2
Example:config>service# epipe 1 customer 1 vc-switching create
config>service>epipe$ endpoint x create
config>service>epipe>endpoint$ exit
config>service>epipe# endpoint y create
config>service>epipe>endpoint# revert-time 0
config>service>epipe>endpoint# exit
config>service>epipe# sap 2/2/2:200 endpoint x create
config>service>epipe>sap$ exit
config>service>epipe# spoke-sdp 3:300 endpoint y primary create
config>service>epipe>spoke-sdp$ revert-timer 0
config>service>epipe>spoke-sdp$ exit
config>service>epipe# spoke-sdp 6:600 endpoint y create
config>service>epipe>spoke-sdp$ precedence 0
config>service>epipe>spoke-sdp$ no shutdown
config>service>epipe>spoke-sdp$ exit
config>service>epipe# no shutdown
The following example displays the configuration:
*A:ALA-T-PE2>config>service>epipe# info
----------------------------------------------
endpoint "x" create
exit
endpoint "y" create
exit
sap 2/2/2:200 endpoint "x" create
exit
spoke-sdp 3:300 endpoint "y" create
precedence primary
revert-time 0

Table of Contents