Installing the Dryer
Step 1: Position and Level the Dryer
Install dryer before washer. This allows room for
attaching exhaust duct.
Install the four rubber feet (in accessories bag).
Installation
Select a location with a solid floor. Dryers installed
in
residential garages must
be
elevated
18
inches (46 em)
above the floor.
No
other fuel burning appliance should
be
installed in
the
same closet with the dryer.
The
dryer must not
be
installed or stored in an area
FRONT
VIEW
SIDE
VIEW
FRONT
VIEW
(wfo Closet Door) (Closet Door)
(Closet Door)
03371
Area
Description
Free Standing/Alcove
Installation
Closet
Installation
A
Dryer sides and rear clearance o
cm
(0 in.) Ocm (0 in.)
CC
Dryer top clearance
30.5 cm (12
in.) 30.5
cm
(12 in.)
C
Dryer front clearance
Not
Applicable
5.1
cm (2 in.)
D
Exhaust duct clearance to combustible
material
5.1
cm (2 in.)
5.1
cm (2 in.)
E
Weather hood
to
ground clearance
30.5 cm (12 in.) 30.5 cm (12 in.)
F
Distance from floor or ceiling
to
hole edge
Not
Applicable
7.6
em
(3
in.)
G*
Area
of
centered air openings
in
closet
door
Not
Applicable
260 sq. cm/open (40 sq. in.)
*Louvered door with equivalent
air openings is acceptable. (Minimum clearances are shown.)
1 Closet Door
2
Centered
Air Openings
(G)
(2
Openings minimum)
3 Outer
Wall
of Enclosure
**NOTE:
For
new
installations,
locate
top
of
wall
vent
106.7
cm
(42
inches)
above
floor
to
make
venting
easier
to
connect.
Figure 3
513082 © Copyright, Alliance Laundry Systems LLC DO NOT
COpy
or TRANSMIT
7