Loading...
Programming Control
14. Cool Down Time
"Cdt-"
This option allows the owner to set the amount
of
cool
down time for all heat cycles.
How
to
Program Cool Down Time
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad until
"Prog"
appears
in
the display. Press the START (enter) keypad and
"AtSH" will appear in the display.
3. Press the
LOW
TEMP
(/\)
or
the
DELICATES
(v)
keypad to scroll through the
programmable options until "Cdt-" appears
in
the display.
4. When "Cdt-" appears in the display, press the
START (enter) keypad. There are four
programmable cool down time options.
Refer to Table
8.
Display
Cooldown Time Options
"Cdt1 " High
Temp
Cool
down
Time
"Cdt2" Medium
Temp
Cooldown Time
"Cdt3"
I Low
Temp
Cooldown
Time
"Cdt4" Delicates Cooldown Time
Table
8
5. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad to select the desired
cooldown time option.
NOTE: Cooldown time can be set from one
(1)
to
15 minutes. The default value for each option
is
3.
6. Press the START (enter) keypad when the correct
option appears in the display.
7. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad to increase
or
decrease
the number
of
minutes displayed to the desired
number
of
minutes.
8. Press the START (enter) keypad
when
the correct
number
of
minutes appears in the display.
The
new value is saved and
the
next option
in
the
parameter will appear in
the
display.
NOTE:
To
program the next op tion,
"tEP
-"
(Temperature), press the MED TEMP
«)
keypad
until
"Cdt-"
is displayed, then press the
LOW
TEMP
(1\)
or
DELICATES
(v)
keypad until
"tEP-
" appears
in
the display and refer to option 15.
To
program other options, refer to the appropriate
section.
How
to
Exit Programming Feature
Press
the
MED TEMP
«)
keypad until the control
returns to Ready Mode.
513001