Programming Control
2.
Coin
#1
Value
"dEn1"
This option allows the owner to set a specific
numerical value for a coin entered. For example, in the
United States the coin value for one quarter would
be
measured in cents (25). Therefore, the coin value
entered for one quarter would 00025.
If
the Heat Vend Price (option 1) is set for "150", and
the
Coin
#1
Value is set for "00025", the vend price
displayed will decrease
by
25 for each coin entered
into coin drop #1.
How
to
Program Coin
#1
Value
1.
Control must
be
in
Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad until
"Prog"
appears in
the display. Press the START (enter) keypad and
"AtSH" will appear in the display.
3. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad to scroll through the
programmable options until
"dEn1"
appears
in
the display.
4. When
"dEn1"
appears in the display, press the
START (enter) keypad. There are five digits
in
the Coin
#1
Value. The fifth digit will appear in
the display and will flash one second on, one
second off. Refer to
Figure
4.
NOTE:
If
the coin value is $100.00
or
more, the
fifth digit is
"1-6".
If
the vend price is $99.99
or
less, the fifth digit is
"0".
CHM507R
Figure 4
5. Press the
LOW
TEMP (/\)
or
the
DELICATES
(v)
keypad to increase
or
decrease
the value
of
the fifth digit.
NOTE:
The
coin value
can
be
set from 1 to 65,535.
The default value is 25.
6. Press the START (enter) keypad to enter the fifth
digit and display remaining four digits. The
active digit will flash one second on and one
second off.
NOTE:
To
go back to
the
current
programmable
option without changing the value press the MED
TEMP
«)
keypad.
7. Press the LOW TEMP (/\)
or
the
DELICATES
(v)
keypad to increase
or
decrease
the
value
of
the active digit and the START
(enter) keypad to enter the value
of
the digit and
advance to the next digit.
8. Press the START (enter) keypad with the last
active digit. The
new
value is saved and the next
option,
"dEn2",
will appear
in
the display.
NOTE: To program
"dEn2"
(Coin
#2
Value), refer
to
option 3.
To
program other options, refer
to
the
appropriate section.
How
to
Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.
24