Programming Control
11.
Error Code Programming
"Err-"
This option allows the owner to turn
on
or
turn
off
certain errors
in
the control.
How
to
Program Error Code Programming
1.
Control must
be
in
Manual Mode. Refer to
Entering the Manual Mode.
2. Press the LOW TEMP
(1\)
or
the
DELICATES
(v)
keypad until
"Prog"
appears
in
the display. Press the START (enter) keypad and
"AtSH" will appear
in
the display.
3. Press the
LOW
TEMP
(1\)
or
the
DELI CATES
(v)
keypad to scroll through the
programmable options until
"Err-"
appears in the
display.
4. When "Err-" appears
in
the display, press the
START (enter) keypad. The control will display
"CEr-". Press the START (enter) keypad. The
control will display
"CEr1".
Refer to Table
5.
"CEr-" Coin Error Parameters
"CEr1"
Coin Error - Detennines
if
display will
show
error.
"CEr2" Coin Error Penalty -
If
enabled,
coin error will erase previous
coins entered and reset the vend
price.
"CEr3"
Coin Drops Header
Present Error -
If
enabled and
coin drop header is unplugged,
control ignores coin inputs.
Table
5
5. Press the LOW TEMP
(1\)
or
the
DELICATES
(v)
keypad to select error code.
6. Press the START (enter) keypad when the correct
code appears in the display. The current status
will appear in the display.
7.
"oFF"
indicates the option is disabled.
"on"
indicates the option is enabled. Press the
LOW
TEMP
(1\)
or
the DELICATES
(v)
keypad
to change the status.
NOTE: The default values for Coin
Error
and Coin
Drops Header
are
on. The default value for Coin
Error
Penalty is oFF.
8. Press the START (enter) keypad when the correct
status appears
in
the display.
The
new value is
saved and the next option in the parameter will
appear
in
the display.
NOTE:
To
program
the next option, "toP-"
(Top-Off Data), press the MED
TEMP
«) keypad
until
"Err-"
is displayed, then press the
LOW
TEMP
(1\)
or
DELICATES (v) keypad until "toP-"
appears
in
the display
and
refer to option 12.
To
program other options, refer to the appropriate
section.
How
to
Exit Programming Feature
Press the
MED
TEMP
«)
keypad until the control
returns to Ready Mode.
34
© Published
by
permission
ofthe
copyright
owner-
DO NOT COPY
or
TRANSMIT
513001