Power Fail Recovery
The Power Fail Recovery feature allows the cycle status
to
be
saved in memory
in
the event
of
a power failure.
If
a cycle is
in
progress when the
power
fails, the cycle
status is saved
in
memory.
When
power recovers, the
control will determine whether to automatically
continue the cycle from the point it left off, requiring
the user to press the START pad to continue the cycle,
or end the cycle and
put
the control into the Ready
Mode. To program this feature, refer to Programming
Control.
Power Fail Reset Disabled
If
the Power Fail feature is disabled, the control will
resume the cycle from the point it left
off
after the
START pad
is
pressed.
Power Fail Reset Enabled
If
the length
of
the power failure is less than the
programmed Power Failure Reset time, the control
will resume the cycle from the point it left off. The
cycle will resume after the START pad is pressed.
If
the power failure lasted more than the programmed
power failure reset time, the control will end the cycle
and will return to the Ready Mode.