Installation
Step 8: Check Heat Source
Electric Dryers
Close
the loading
door
and start the dryer in a
heat
setting (refer
to
the
Operation
section). After the
dryer
has
operated for three minutes, the exhaust
air
or
exhaust
pipe should
be
warm.
Gas Dryers
IMPORTANT: This
operation
is
to
be
conducted
by
qualified personnel only.
To
view
the
burner
flame,
remove
the
lower
front
panel
of
the dryer.
Close
the
loading door, start the
dryer
in
a
heat
setting
(refer
to
the
Operation
section).
The
dryer will start,
the igniter will
glow
red
and
the
main
burner
will
ignite.
IMPORTANT:
If
all
air
is
not
purged
out
of
gas
line, gas
igniter
may
go
off
before gas is ignited.
If
this
happens,
after
approximately two
minutes
igniter
will
again
attempt
gas ignition.
IMPORTANT:
If
igniter does
not
light,
make
sure
gas is
turned
on.
After the dryer has operated for approximately five
minutes, observe burner flame through
lower
front
panel. Adjust the air shutter
to
obtain a soft,
unifonn
blue
flame.
(A
lazy, yellow-tipped flame indicates lack
of
air. A harsh, roaring,
very
blue flame indicates too
much
air.) Adjust
the
air shutter as follows:
1. Loosen the
air
shutter locks crew.
2.
Turn
the air shutter to the left to get a luminous
yellow-tipped flame,
then
tum it
back
slowly to
the right to obtain a steady, soft
blue
flame.
3.
After the
air
shutter is adjusted
for
proper
flame,
tighten the
air shutter lockscrew securely.
4. Reinstall the
lower
front panel.
AI
WARNING
For personal safety, lower
front
panel
must
be in place
during
normal operation.
W046
After
the dryer
has
operated for approximately three
minutes, exhaust
air
or
exhaust
pipe
should
be
warm.
DRY2235N
1
2
3
4
Closed Position
Shut-Off Valve Handle
Air Shutter Lockscrew
Air
Shutter
5
6
3.1
mm (1/8 in.) Pipe Plug
(For checking manifold pressure)
Open Position
Figure 28
513082
© Copyright, Alliance Laundry Systems LLC - DO NOT