7.
Default Cycle "dCYC"
This option allows the owner to set the default cycle
the machine will enter when
in
the Ready Mode.
When programming the default cycle, refer to
Table 3.
How to Program Default Cycle
1.
Control must
be
in
Manual Mode. Refer to
Entering the Manual Mode.
2. Press the
LOW
TEMP
(1\)
or
the
DELICATES
(v) keypad until "Prog" appears in
the display. Press the START (enter) keypad and
"AtSH"
will appear in the display.
3. Press the LOW TEMP
(1\)
or
the
DELI CATES
(v)
keypad to scroll through the
programmable options until
"dCYC" appears in
the display.
4.
When "dCYC" appears in the display, press the
START (enter) keypad. A number will appear in
the display. This
number
corresponds to the
current default cycle value. Refer to
Table 3.
5.
Press the
LOW
TEMP
(1\)
or
the
DELICATES
(v)
keypad to increase
or
decrease
the current number to the desired number selected
from
Table 3.
6. Press the START (enter) keypad when the correct
number appears in the display.
The
new
value is
saved and the
next
option, "oPL", will appear in
the display.
NOTE:
To
program "oPL" (OPL Mode), refer to
option
8.
To
program
other
options, refer to the
appropriate section.
How
to
Exit Programming Feature
Press the
MED
TEMP
«)
keypad until the control
returns to Ready Mode.
Programming Control
How
to
Read Table 3
To detennine the correct number required to program
Default Cycle,
use
the following table.
The
Default
Value column contains the number required
in
step 5.
The corresponding cycle LED will
be
lit while
selecting a default cycle. For example, when the
display shows
"5", the Delicates LED
is
lit.
"dCYC"
Default Cycle Value
Cycle Type
1
HIGH
TEMP
2
LOW
TEMP
3
NO
HEAT
4
:MEDTEMP
5
DELICATES
Table
3
NOTE: The default cycle programmed
at
the
factory is 4, Med Temp.