Programming Control
1.
Heat
Vend
Price "AtSH"
This option allows the owner to set the vend price for a
heated cycle. This vend price will
be
shown in the
display when in Ready Mode.
How to Program Heat Vend Price
1.
Control must be
in
Manual Mode. Refer to
Entering the Manual Mode.
2.
Press the LOW TEMP (/\) or the
DELICATES
(v)
keypad until
"Prog"
appears in
the display. Press the START (enter) keypad.
3.
"AtSH" will appear
in
the display. Press the
START
(enter) keypad.
4. There are five digits in the Heat Vend Price.
The
fifth digit will appear in the display and will flash
one second on, one second off.
NOTE:
If
the vend price is $100.00
or
more, the
fifth digit is "1-6".
If
the vend price is $99.99
or
less, the fifth digit is
"0".
[
~
.
,,~~/~
]
CHM507R
Figure 3
5. Press the LOW
TEMP
(/\)
or
the
DELICATES
(v)
keypad to increase
or
decrease
the value
of
the fifth digit.
NOTE: The vend price
can
be
set from 0 to 65,535.
The default value is 200.
6. Press the START (enter) keypad to enter the fifth
digit and display remaining four digits.
The
active digit will flash one second on and one
second off.
NOTE:
To
go
back to the
current
programmable
option without changing the value press the
MED
TEMP
«)
keypad.
7. Press the LOW TEMP (/\) or the
DELI CATES
(v)
keypad to increase or decrease
the value
of
the active digit and the START
(enter) keypad to enter the value
of
the digit and
advance to the next digit.
8.
Press the START (enter) keypad with the last
active digit. The new value is saved and the next
option,
"dEn1",
will appear in the display.
NOTE:
To
program
"dEn1"
(Coin
#1
Value), refer
to
option 2.
To
program other options, refer to
the
appropriate section.
How to Exit Programming Feature
Press the MED TEMP
«)
keypad until the control
returns to Ready Mode.